4
 
 

Refrigeration Test Rig

Description:
 

The REFRIGERATION test rig works on simple vapour compression refrigeration cycle and uses R134a as a refrigerant. It is environment friendly. The system is fabricated such that students can observe and study vapour compression cycle, its component principle & working. The arrangement of parts such that, all the parts are visible and working can be easily understood.

 

Technical Specifications:

SUB-TITLE

PARAMETER

DESCRIPTION

 

MODEL

NAERF-01E

REFRIGERATION
SYSTEM

Cooling
Capacity

450 Watts at rated test conditions* ( 1/8 TR )

 

Compressor

1/4 HP; Hermetically sealed. Make: Emerson Climate Technologies Ltd. /or Danfoss Ltd;/or  Tecumseh Products India Ltd./ or any equivalent make.

 

Condenser

Forced convection air cooled.

 

Condenser fan

Axial flow type.

 

Drier/ filter

Molecular sieve type.

 

Expansion device

Capillary tube

 

Evaporator

Direct expansion type. Shell & Coil type provided

 

Accumulator

Copper / M.S. shell suction line accumulator provided.

 

Refrigerant

R-134 a.

CONTROLS & INDICATIONS

HP / LP Cut-out

Alco/  Danfoss / Castle or equivalent make.

 

Pressure indication

2 nos. dial type pressure gauges; one for suction and the other for discharge pressure.

 

Temperature indication

Multi-channel  LED digital temperature indicator.

 

Refrigerant flow indication

Glass tube rotameter.

ELECTRICAL SYSTEM

Supply

220-240 Volts, 50 Hz, 1 phase.

Input power

1.0 kW.

Rated current

 4.5 Amps.

Operating switches

Main switch & piano type switches for compressor & heater

Indicating lamps

Provided for compressor.

Energy-meters

Provided for compressor.

CONSTRUCTION

Material

Panel : 1.2 mm thick CRCA

Outer finish

Powder coating

Calorimeter

Stainless steel: SS-304 tank with nitrile foam insulation.

Size

900 x 600 x 1130 mm  (L x B x H)

Refrigeration Test Rig
Request Quote
List of Experiments:
 

1. TO STUDY VARIOUS COMPONENTS AND CONTROLS USED IN VAPOUR COMPRESSION CYCLE.
2.To evaluate the tonnage capacity of the air conditioning system by enthalpy difference method.
3. TO EVALUATE ACTUAL & THEORETICAL C.O.P. OF VAPOUR COMPRESSION CYCLE.
4. TO PLOT ACTUAL REFRIGERATION CYCLE ON P-H CHART. 

 

Rating conditions * : Ambient temperature = 350 C, atmospheric pressure = 1.01 bar, suction pressure = 35 psig, discharge pressure = 180 psig, evaporation temperature = 7.70 C, discharge temperature = 550 C. 

AIR CONDITIONING TEST RIG

Description:
 

The A.C. test rig works on simple vapour   compression refrigeration
cycle using R 134 a  as a refrigerant.
The system is fabricated such that student can study all the air conditioning 
processes.  It is also useful to understand working of all the components of system, their performance and control etc.
     All the components are mounted on the display board, so that students  can observe their working easily.

 

Technical Specifications:

SUB-TITLE

PARAMETER

DESCRIPTION

MODEL

NAEAC-01E

REFRIGERATION
SYSTEM

Capacity

0.30 TR @Rated test conditions

Compressor

Hermetically sealed. Make :Emerson Climate Tech./ Tecumseh Products India Ltd./ Danfoss Ltd./or any equivalent make.

Condenser

Forced convection air cooled.

Condenser fan

Axial flow.

Drier/ filter

Provided.

Expansion device

Capillary Tube.

Evaporator

Forced convection air cooled.

Evaporator Fan

Axial Flow Type

Dehumidifier or Reheater

1000 Watts; Finned Type.

Humidifier

Provided

Refrigerant

R-134 a.

CONTROLS & INDICATIONS

HP / LP Cut-out

Alco/ or Danfoss / Castle or equivalent make.

Temperature

6 Channel facility with digital display.

Pressure

2 Nos.; Dial type pressure gauges.

Refrigerant Flow

Glass tube Rotameter provided.

Air temperature

DBT & WBT measurement by sling psychrometer.

Air flow measurement

By inclined tube manometer.

ELECTRICAL SYSTEM

Supply

220-240 Volts, 50 Hz, 1 phase.

Input power

1.2 kW.

Rated current

5.5 Amps.

Indicating lamps

Provided for compressor and heater.

Energy-meters

Range 0-20 A; provided for Compressor

CONSTRUCTION

Material

Panel: 1.2 mm thick CRCA

Outer finish

Powder coating

Size

900 x 600 x 1480 (L x B x H)

AIR CONDITIONING TEST RIG
Request Quote
List of Experiments:

To evaluate the tonnage capacity of the air conditioning system by enthalpy difference method.

  1. To evaluate actual and theoretical C.O.P. of the system.
  2. To plot the refrigeration cycle on P-H & T-S charts.
  3. To plot the psychrometric processes on psychrometric charts.

Rating conditions * : Ambient temperature= 350 C, atmospheric pressure = 1.01 bar, suction pressure = 70 psig, discharge pressure = 300 psig, evaporation temperature = 7.70 C, discharge temperature = 550 C. 

WATER COOLER TEST RIG

Description:
 

‘THE WATER COOLER’ Test Rig enables students to study and understand Vapour Compression Cycle, its components, principle and working. All the components are mounted on rigid steel frame. The trainer consists of a hermetically sealed compressor, forced convection air-cooled condenser, filter / drier, flow meter, expansion device and coil wound type evaporator. Separate pressure gauges are provided to record suction and discharge pressures and digital temperature indicators for various temperatures.
The refrigerant used is R-134 a which is environment friendly.

 

Technical Specifications:

SUB-TITLE

PARAMETER

DESCRIPTION

MODEL

NAEAC-01E

REFRIGERATION
SYSTEM

Capacity

0.30 TR @Rated test conditions

Compressor

Hermetically sealed. Make :Emerson Climate Tech./ Tecumseh Products India Ltd./ Danfoss Ltd./or any equivalent make.

Condenser

Forced convection air cooled.

Condenser fan

Axial flow.

Evaporator

Provided.

Expansion device

Capillary Tube.

Accumulator

Forced convection air cooled.

Insulation

Axial Flow Type

Refrigerant

1000 Watts; Finned Type.

CONTROLS & INDICATIONS

Provided

Temperature

R-134 a.

Pressure

Alco/ or Danfoss / Castle or equivalent make.

ELECTRICAL SYSTEM

Supply

6 Channel facility with digital display.

Input power

2 Nos.; Dial type pressure gauges.

Rated current

Glass tube Rotameter provided.

Energy-meters

DBT & WBT measurement by sling psychrometer.

CONSTRUCTION

Water Tank

By inclined tube manometer.

Outer body

220-240 Volts, 50 Hz, 1 phase.

Size

1.2 kW.

 
WATER COOLER TEST RIG
Request Quote
List of Experiments:
 
  • To study various components and controls used in Vapour Compression Cycle.
  • To evaluate the cooling capacity of water cooler.
  • To evaluate actual and theoretical C.O.P. of Vapour Compression Cycle.
  • To plot the actual Refrigeration Cycle on P-H and T-S charts.
 
   
 
   
Water Chiller | Printing Chiller | Educational Test Rig | Refrigeration Test Rig | Air Conditioning Test Rig | Water Cooler Test Rig | Ice Plant Test Rig | Mechanical Heat Pump Test Rig | Computerised Heat Pump Test Rig | Vapour Absorption Test Rig | Cascade System Test Rig | Vortex Tube Test Rig | Cut-Section Models Of Various Compressors | Display Board Containing Various Controls & Components Used In Rac | Oil Cooler - Oil Chiller | Sample Gas Coolers | Panel Air Conditioners